Description
Electronic Xenon igniter for direct lamp fit on.
Regulatory Specifications
Safety · Safety approval together with HBX 180 / 300
RoHS · According to 2002/95/EC

Messtechnik
Lichttechnik PQUBE ,ENEIDA

Elektrische Messtechnik Prüfgeräte nach VDE u.v.m.

Power Quality Analysen
ohne Kompromisse.

Monitoring & Optimierung
des Niederspannungsverteilnetzes

Revolutionary system: no external power required, self-synchronisation with ballast Features To the price Request

Xe / Hg Electronic Ballasts Power Ranges 50 – 3000W
Electronic Xenon igniter for direct lamp fit on.
| TECHNICAL DATA | |
|---|---|
| Rated current | 22 A |
| Temporary over current < 90 s within a period of 1 min. | 25 A |
| Ignition voltage | ± 14 kVp |
| Input voltage range | DC 0-140 V / threshold for ignition > 70 V |
| Operation mode | Symmetrical |
| Ignition mode control | Self stopping feature, 1sec operating, self sourcing by ballast, no external Source necessary |
| Pulse rate | Approximately 50/sec. @ 90 V |
| Repetition rate | depend on ballast, break of min.10 sec. is required |
| Case temperature | 90°C max at potting surface near main coil |
| Cable length to lamp | Direct contacting, no cables nescessary |
| Dimensions (L x W x H) | 95 x 60 x 27 mm excl. contacts |
| Weight | 160 g ± 5 g |
| Connectors | 2 x M4 and 2 x M3 screw terminals, torque: M4 = 1.2 Nm, M3 = 0.9 Nm |